LZSR Current Transducer Sensors

LEM LZSR Current Transducer Sensors are designed for precise measurement of DC, AC, and pulse currents, ranging from 80ARMS to 200ARMS, while ensuring galvanic isolation between primary and secondary circuits. These sensors offer outstanding performance with ultra-low offset drift as low as 3ppm/K, a significant improvement over previous generations that relied on traditional Hall-effect chips. Additional features include reference access, an overcurrent detection output, and operation on a +5V power supply, making the components highly efficient for various industrial applications.

Rezultatai: 8
Pasirinkite Vaizdas Dalies Nr. Gam. Aprašymas Duomenų Lapas Prieinamumas Kainodara (EUR) Filtruokite lentelėje pateiktus rezultatus pagal vieneto kainą, remdamiesi kiekiu. Qty. RoHS ECAD modelis Dabartinė klasė Jutiklio Type Reakcijos Laikas Tikslumas Dažnių diapazonas Darbinė Maitinimo Įtampa Išvesties Type Didžiausia darbinė temperatūra Minimali darbinė temperatūra Maksimali Maitinimo Įtampa Maitinimo Įtampa - Min. Tipas
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 100-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 91Prieinamumas
Min.: 1
Daugkart.: 1

100 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 150-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 81Prieinamumas
Min.: 1
Daugkart.: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 200-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 95Prieinamumas
Min.: 1
Daugkart.: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 80-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 133Prieinamumas
Min.: 1
Daugkart.: 1

80 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 100-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 55Prieinamumas
Min.: 1
Daugkart.: 1

100 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 150-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 48Prieinamumas
60Tikėtina 2026-10-30
Min.: 1
Daugkart.: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 150-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 44Prieinamumas
Min.: 1
Daugkart.: 1

150 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer
LEM Prie plokštės tvirtinami srovės jutikliai Current Transducer LZSR 200-TP/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 12Prieinamumas
60Tikėtina 2026-09-18
Min.: 1
Daugkart.: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog + 85 C - 40 C 5.25 V 4.75 V Current Transducer