Banner Engineering Saugos valdikliai

Rezultatai: 21
Pasirinkite Vaizdas Dalies Nr. Gam. Aprašymas Duomenų Lapas Prieinamumas Kainodara (EUR) Filtruokite lentelėje pateiktus rezultatus pagal vieneto kainą, remdamiesi kiekiu. Qty. RoHS ECAD modelis Įėjimų skaičius Išėjimų skaičius Maksimali Maitinimo Įtampa Maitinimo Įtampa - Min. Montavimo stilius Dydis Interface Type Serija
Banner Engineering Saugos valdikliai Relay Module for Safety Light Curtain/Control with EDM; Supply Voltage: 24 V dc; Safety Input: 1 Dual/Single Channel; Safety Output: 3 NO, 6 A; Aux Output: None; Spring Clamp Terminals; Width: 22.5 mm
17Prieinamumas
Min.: 1
Daugkart.: 1
Banner Engineering Saugos valdikliai XS26-ISDd Safety Controller: Expandable; ISD Compatible (8 ISD Chains) 26 Input 2 pairs of PNP Safety Outputs (0.5 A each); Display; Ethernet USB; 8 Convertible Inputs; Removable Screw Terminals 24 V dc; 160 mA
2Prieinamumas
Min.: 1
Daugkart.: 1
26 Input 4 Output 10 mm x 45 mm x 129 mm Ethernet, Micro USB XS26
Banner Engineering Saugos valdikliai Safety Controller EtherCAT Communication Gateway; Used with Ethernet Capable XS26 Saugos valdikliai with FID6 or later
3Prieinamumas
Min.: 1
Daugkart.: 1

DIN Rail Mount XS
Banner Engineering Saugos valdikliai Safety Controller Expansion Module: Dual Relay Output Module; Safety Outputs: 4 NO, 6 A; Aux Outputs: 2 NC, 2.5 A; Used with XS26-2 Saugos valdikliai
43Prieinamumas
Min.: 1
Daugkart.: 1
2 Input 4 Output DIN Rail Mount 110 mm x 22.5 mm x 129 mm XS


Banner Engineering Saugos valdikliai Safety Controller Three-Output Interface Module; 10 A Isolated Mechanical Contacts; 9 normally open plus 3 normally closed monitor contacts 3Prieinamumas
Min.: 1
Daugkart.: 1
SC22 SAFETY CONTROLLER
Banner Engineering Saugos valdikliai SC10-2roe Safety Controller; ISD Compatible (2 ISD Chains) 10 Inputs 2 Relay Outputs (3 NO, 6 A each); Terminal LEDs; 4 Convertible Inputs; Push-In Spring Clamp Terminals; 24 V dc; 240-580 mA
12Prieinamumas
32Pagal užsakymą
Min.: 1
Daugkart.: 1
Ethernet, Micro USB SC10-2
Banner Engineering Saugos valdikliai SC26-2D Safety Controller: Non Expandable; 26 Input; 2 pairs of PNP Safety Outputs (0.5 A each); Display; No Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 120 mA
4Prieinamumas
Min.: 1
Daugkart.: 1
26 Input 4 Output 24 VDC DIN Rail Mount 10 mm x 45 mm x 129 mm SC26
Banner Engineering Saugos valdikliai SC26-2DE Safety Controller: Non Expandable; 26 Input; 2 pairs of PNP Safety Outputs (0.5 A each); Display; Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 160 mA
2Prieinamumas
5Tikėtina 2026-02-16
Min.: 1
Daugkart.: 1
Ethernet, Micro USB SC26
Banner Engineering Saugos valdikliai Safety Controller Expansion Module: 16 Terminal Input Module; 4 Convertible inputs; Removable Screw Terminals; Used with XS26-2 Saugos valdikliai
4Prieinamumas
Min.: 1
Daugkart.: 1
16 Input DIN Rail Mount 110 mm x 22.5 mm x 129 mm XS
Banner Engineering Saugos valdikliai XS26-2D Safety Controller: Expandable; 26 Input; 2 pairs of PNP Safety Outputs (0.5 A each); Display; No Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 120 mA
4Prieinamumas
Min.: 1
Daugkart.: 1
26 Input 4 Output 10 mm x 45 mm x 129 mm XS26
Banner Engineering Saugos valdikliai XS26-2DE Safety Controller: Expandable; 26 Input; 2 pairs of PNP Safety Outputs (0.5 A each); Display; Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 160 mA
5Prieinamumas
Min.: 1
Daugkart.: 1
26 Input 4 Output 10 mm x 45 mm x 129 mm XS26
Banner Engineering Saugos valdikliai Safety Controller Expansion Module: Solid-State Output Module; 4 pairs of PNP Safety Outputs (0.5 A each); Used with XS26-2 Saugos valdikliai
7Prieinamumas
Min.: 1
Daugkart.: 1
4 Output 28.8 VDC 19.2 VDC DIN Rail Mount 110 mm x 22.5 mm x 129 mm XS
Banner Engineering Saugos valdikliai Safety Controller Expansion Module: Relay Output Module; Safety Outputs: 2 NO, 6 A; Aux Outputs: 1 NC, 2.5 A; Used with XS26-2 Saugos valdikliai
2Prieinamumas
Min.: 1
Daugkart.: 1
3 Output DIN Rail Mount 110 mm x 22.5 mm x 129 mm XS
Banner Engineering Saugos valdikliai XS26-2E Safety Controller: Expandable; 26 Input; 2 Pairs of PNP Safety Outputs (0.5 A each); No Display; Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 140 mA
1Prieinamumas
Min.: 1
Daugkart.: 1
26 Input 4 Output 10 mm x 45 mm x 129 mm XS26
Banner Engineering Saugos valdikliai Safety Controller Expansion Module: Solid-State Output Module; 2 pairs of PNP Safety Outputs (0.75 A each); Used with XS26-2 Saugos valdikliai
2Prieinamumas
Min.: 1
Daugkart.: 1
2 Output 28.8 VDC 19.2 VDC DIN Rail Mount 110 mm x 22.5 mm x 129 mm XS
Banner Engineering Saugos valdikliai Safety Relay Module for Two-Hand Control Buttons; Supply Voltage: 24 V ac/dc; Safety Input: Two Buttons With Complementary PNP or Relay Outputs; Safety Output: 2 NO, 6 A; Aux Output: None; Terminal Block: Removable; Width: 22.5 mm; Self-Checking Circ
22Tikėtina 2026-02-16
Min.: 1
Daugkart.: 1
24 VAC, 24 VDC 24 VAC, 24 VDC DIN Rail Mount 118 mm x 84 mm x 22.5 mm DUO-TOUCH MODULES
Banner Engineering Saugos valdikliai SC26-2 Safety Controller: Non Expandable; 26 Input; 2 pairs of PNP Safety Outputs (0.5 A each); No Display; No Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 100 mA
Ne Sandėlyje Esančių Prekių Pristatymo Laikas 3 Savaičių
Min.: 1
Daugkart.: 1
SC26
Banner Engineering Saugos valdikliai SC26-2E Safety Controller: Non Expandable; 26 Input; 2 pairs of PNP Safety Outputs (0.5 A each); No Display; Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 140 mA
Ne Sandėlyje Esančių Prekių Pristatymo Laikas 3 Savaičių
Min.: 1
Daugkart.: 1
SC26
Banner Engineering Saugos valdikliai Relay Module for Safety Light Curtain/Control with EDM; Supply Voltage: 24 V dc; Safety Input: 1 Dual/Single Channel; Safety Output: 2 NO, 6 A; Aux Output: 1 NC, 6 A; Spring Clamp Terminals; Width: 22.5 mm
Ne Sandėlyje Esančių Prekių Pristatymo Laikas 3 Savaičių
Min.: 1
Daugkart.: 1
Banner Engineering Saugos valdikliai XS26-2 Safety Controller: Expandable; 26 Input; 2 pairs of PNP Safety Outputs (0.5 A each); No Display; No Ethernet; USB; 8 Convertible Inputs; Removable Screw Terminals; 24 V dc; 100 mA
Ne Sandėlyje Esančių Prekių Pristatymo Laikas 3 Savaičių
Min.: 1
Daugkart.: 1
XS26
Banner Engineering Saugos valdikliai Safety Controller Expansion Module: 8 Terminal Input Module; 2 Convertible inputs; Removable Screw Terminals; Used with XS26-2 Saugos valdikliai
Ne Sandėlyje Esančių Prekių Pristatymo Laikas 3 Savaičių
Min.: 1
Daugkart.: 1
8 Input 24 VDC DIN Rail Mount 110 mm x 22.5 mm x 129 mm XS