MAX86178ENJ+T

Analog Devices / Maxim Integrated
700-MAX86178ENJ+T
MAX86178ENJ+T

Gam.:

Aprašymas:
Analoginė priekinė dalis - AFE ECG+PPG+BIOZ AFE

ECAD modelis:
Atsisiųskite nemokamą Library Loader, kad galėtumėte konvertuoti šį failą darbui su ECAD įrankiu. Sužinokite daugiau apie ECAD Modelį.

Prieinamumas: 2 928

Turime sandėlyje:
2 928 Galime išsiųsti iš karto
Gamintojo numatytas pristatymo laikas
10 Savaičių Apytikriai apskaičiuotas gamybos laikas gamykloje, jei dalių kiekis didesnis nei nurodyta.
Min. 1   Užsakoma po 1
Vieneto kaina:
-,-- €
Plėt. Kaina:
-,-- €
Numatomas Įkainis:

Kainodara (EUR)

Qty. Vieneto kaina
Plėt. Kaina
14,30 € 14,30 €
11,22 € 112,20 €
10,76 € 269,00 €
9,48 € 948,00 €
9,01 € 2 252,50 €
8,44 € 4 220,00 €
7,83 € 7 830,00 €
Visa Ritė (Užsakoma po 2500)
7,83 € 19 575,00 €

Produkto Požymis Atributo vertė Pasirinkite Požymį
Analog Devices Inc.
Gaminio kategorija: Analoginė priekinė dalis - AFE
RoHS:  
Reel
Cut Tape
Prekės Ženklas: Analog Devices / Maxim Integrated
Gaminio tipas: Analog Front End - AFE
Gamyklinės pakuotės kiekis: 2500
Subkategorija: Data Converter ICs
Rasta produktų:
Norėdami rodyti panašius produktus, pažymėkite bent vieną langelį
Pasirinkite bent vieną žymimąjį langelį, kad būtų rodomi panašūs šios kategorijos produktai.
Pasirinkti atributai: 0

CNHTS:
8542399000
CAHTS:
8542390000
USHTS:
8542390090
MXHTS:
8542399999
ECCN:
EAR99

Data Converters

Analog Devices Inc. Data Converters are a portfolio of data converters that are unmatched in ability and deliver performance with value. The converters provide accurate and reliable conversion for a range of applications. Typical applications include industrial automation, programmable logic controllers, optical transceivers, data acquisition, and more.

MAX86178 Ultra-Low-Power Medical AFE Sensor

Analog Devices MAX86178 Ultra-Low-Power Medical-Grade AFE Sensor is a highly integrated, multiple vital-sign monitoring device with a complete photoplethysmogram (PPG), electrocardiogram (ECG), and biopotential (BioZ) analog front-end (AFE) for wearable applications. The three sensor channels are synchronized. The PPG data acquisition system supports up to six LEDs and four photodiode inputs, and the LEDs are programmable from two high-current, 8-bit LED drivers. The ECG channel features EMI filtering, internal lead biasing, right-leg drive, and extensive calibration voltages for built-in self-testing. The BioZ receive channel has EMI filtering and extensive calibration features with high input impedance, low noise, programmable gain, low-/high-pass filter options, and a high-resolution ADC.