Per KEMET, part number C1206H104F3GACTU is a more expensive part than others because it is a 200?C rated part designed primarily for the Oil & Gas Industry. It is very conservative design (think miliary-like design rules inside the MLCC), a special dielectric to have very higher IR (insulation resistance) at high temperatures, followed by a rigorous screening protocol (100% medical grade visual inspection, 100% burn-in (voltage conditioning) with strict PDA, 100% electrical screening, 100% C-SAM (acoustical screening). Please contact a Mouser Technical Sales Representative for further information. 5-0123-2